| Minimum order quantity | Volume Discount | Input Type | Response Speed (ms) | Conversion accuracy (%FS) | Output type | Number Of Inputs (Point) | Number of Outputs (Point) | Power Supply | Standard | Dimension length (mm) | Dimension width (mm) | Dimension thickness (mm) | Classification | Temperature Range | First input signal range | Second input signal range | Second output signal | Input thermocouple | Power consumption (current) | Mounting Method | Note | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
331.45 € | 1 | Available | 23 Days | Voltage (DC) | 25 | ±0.1 | [Other] 1 to 5 V | 1 | 1 | AC 100–240 | CE | 84 | 23 | 106.5 | Isolation converter (isolator) | - | DC±10 V | - | - | - | 4.5VA(AC) | DIN rail/wall surface | - | |
331.45 € | 1 | Available | 23 Days | Voltage (DC) | 25 | ±0.1 | 0 to 10 V | 1 | 1 | AC 100–240 | CE | 84 | 23 | 106.5 | Isolation converter (isolator) | - | DC±10 V | - | - | - | 4.5VA(AC) | DIN rail/wall surface | - | |
331.45 € | 1 | Available | 23 Days | Voltage (DC) | 25 | ±0.1 | ±10 V | 1 | 1 | AC 100–240 | CE | 84 | 23 | 106.5 | Isolation converter (isolator) | - | DC±10 V | - | - | - | 4.5VA(AC) | DIN rail/wall surface | - | |
331.45 € | 1 | Available | 23 Days | Voltage (DC) | 25 | ±0.1 | 4 to 20mA | 1 | 1 | AC 100–240 | CE | 84 | 23 | 106.5 | Isolation converter (isolator) | - | DC 4–20 mA | - | - | - | 4.5VA(AC) | DIN rail/wall surface | - | |
331.45 € | 1 | Available | 23 Days | Voltage (DC) | 25 | ±0.1 | [Other] 1 to 5 V | 1 | 1 | AC 100–240 | CE | 84 | 23 | 106.5 | Isolation converter (isolator) | - | DC 4–20 mA | - | - | - | 4.5VA(AC) | DIN rail/wall surface | - | |
331.45 € | 1 | Available | 23 Days | Voltage (DC) | 25 | ±0.1 | 0 to 10 V | 1 | 1 | AC 100–240 | CE | 84 | 23 | 106.5 | Isolation converter (isolator) | - | DC 4–20 mA | - | - | - | 4.5VA(AC) | DIN rail/wall surface | - | |
331.45 € | 1 | Available | 23 Days | Voltage (DC) | 25 | ±0.1 | ±10 V | 1 | 1 | AC 100–240 | CE | 84 | 23 | 106.5 | Isolation converter (isolator) | - | DC 4–20 mA | - | - | - | 4.5VA(AC) | DIN rail/wall surface | - | |
468.87 € | 1 | 23 Days | Voltage (DC) | 25 | ±0.1 | 4 to 20mA | 1 | 2 | AC 100–240 | CE | 84 | 29.5 | 106.5 | Dual-output isolation converter (isolator) | - | DC1 to 5V | - | DC 4–20 mA | - | - | DIN rail/wall surface | - | ||
468.87 € | 1 | 23 Days | Voltage (DC) | 25 | ±0.1 | 4 to 20mA | 1 | 2 | AC 100–240 | CE | 84 | 29.5 | 106.5 | Dual-output isolation converter (isolator) | - | DC1 to 5V | - | DC0 to 10V | - | - | DIN rail/wall surface | - | ||
468.87 € | 1 | 23 Days | Voltage (DC) | 25 | ±0.1 | 4 to 20mA | 1 | 2 | AC 100–240 | CE | 84 | 29.5 | 106.5 | Dual-output isolation converter (isolator) | - | DC1 to 5V | - | DC±10 V | - | - | DIN rail/wall surface | - | ||
468.87 € | 1 | Available | 23 Days | Voltage (DC) | 25 | ±0.1 | 0 to 10 V | 1 | 2 | AC 100–240 | CE | 84 | 29.5 | 106.5 | Dual-output isolation converter (isolator) | - | DC1 to 5V | - | DC0 to 10V | - | - | DIN rail/wall surface | - | |
468.87 € | 1 | Available | 23 Days | Voltage (DC) | 25 | ±0.1 | 0 to 10 V | 1 | 2 | AC 100–240 | CE | 84 | 29.5 | 106.5 | Dual-output isolation converter (isolator) | - | DC1 to 5V | - | DC±10 V | - | - | DIN rail/wall surface | - | |
468.87 € | 1 | Available | 23 Days | Voltage (DC) | 25 | ±0.1 | ±10 V | 1 | 2 | AC 100–240 | CE | 84 | 29.5 | 106.5 | Dual-output isolation converter (isolator) | - | DC1 to 5V | - | DC±10 V | - | - | DIN rail/wall surface | - | |
468.87 € | 1 | 23 Days | Voltage (DC) | 25 | ±0.1 | 4 to 20mA | 1 | 2 | AC 100–240 | CE | 84 | 29.5 | 106.5 | Dual-output isolation converter (isolator) | - | DC0 to 10V | - | DC 4–20 mA | - | - | DIN rail/wall surface | - | ||
468.87 € | 1 | 23 Days | Voltage (DC) | 25 | ±0.1 | 4 to 20mA | 1 | 2 | AC 100–240 | CE | 84 | 29.5 | 106.5 | Dual-output isolation converter (isolator) | - | DC0 to 10V | - | DC0 to 10V | - | - | DIN rail/wall surface | - | ||
468.87 € | 1 | 23 Days | Voltage (DC) | 25 | ±0.1 | 4 to 20mA | 1 | 2 | AC 100–240 | CE | 84 | 29.5 | 106.5 | Dual-output isolation converter (isolator) | - | DC0 to 10V | - | DC±10 V | - | - | DIN rail/wall surface | - | ||
468.87 € | 1 | Available | 23 Days | Voltage (DC) | 25 | ±0.1 | 0 to 10 V | 1 | 2 | AC 100–240 | CE | 84 | 29.5 | 106.5 | Dual-output isolation converter (isolator) | - | DC0 to 10V | - | DC0 to 10V | - | - | DIN rail/wall surface | - | |
468.87 € | 1 | Available | 23 Days | Voltage (DC) | 25 | ±0.1 | 0 to 10 V | 1 | 2 | AC 100–240 | CE | 84 | 29.5 | 106.5 | Dual-output isolation converter (isolator) | - | DC0 to 10V | - | DC±10 V | - | - | DIN rail/wall surface | - | |
468.87 € | 1 | Available | 23 Days | Voltage (DC) | 25 | ±0.1 | ±10 V | 1 | 2 | AC 100–240 | CE | 84 | 29.5 | 106.5 | Dual-output isolation converter (isolator) | - | DC0 to 10V | - | DC±10 V | - | - | DIN rail/wall surface | - | |
468.87 € | 1 | 23 Days | Voltage (DC) | 25 | ±0.1 | 4 to 20mA | 1 | 2 | AC 100–240 | CE | 84 | 29.5 | 106.5 | Dual-output isolation converter (isolator) | - | DC±10 V | - | DC 4–20 mA | - | - | DIN rail/wall surface | - | ||
468.87 € | 1 | 23 Days | Voltage (DC) | 25 | ±0.1 | 4 to 20mA | 1 | 2 | AC 100–240 | CE | 84 | 29.5 | 106.5 | Dual-output isolation converter (isolator) | - | DC±10 V | - | DC0 to 10V | - | - | DIN rail/wall surface | - | ||
468.87 € | 1 | 23 Days | Voltage (DC) | 25 | ±0.1 | 4 to 20mA | 1 | 2 | AC 100–240 | CE | 84 | 29.5 | 106.5 | Dual-output isolation converter (isolator) | - | DC±10 V | - | DC±10 V | - | - | DIN rail/wall surface | - | ||
468.87 € | 1 | 23 Days | Voltage (DC) | 25 | ±0.1 | 0 to 10 V | 1 | 2 | AC 100–240 | CE | 84 | 29.5 | 106.5 | Dual-output isolation converter (isolator) | - | DC±10 V | - | DC0 to 10V | - | - | DIN rail/wall surface | - | ||
468.87 € | 1 | 23 Days | Voltage (DC) | 25 | ±0.1 | 0 to 10 V | 1 | 2 | AC 100–240 | CE | 84 | 29.5 | 106.5 | Dual-output isolation converter (isolator) | - | DC±10 V | - | DC±10 V | - | - | DIN rail/wall surface | - | ||
468.87 € | 1 | 23 Days | Voltage (DC) | 25 | ±0.1 | ±10 V | 1 | 2 | AC 100–240 | CE | 84 | 29.5 | 106.5 | Dual-output isolation converter (isolator) | - | DC±10 V | - | DC±10 V | - | - | DIN rail/wall surface | - | ||
468.87 € | 1 | Available | 5 Days | [Current (AC/DC)] Current (DC) | 25 | ±0.1 | 4 to 20mA | 1 | 2 | AC 100–240 | CE | 84 | 29.5 | 106.5 | Dual-output isolation converter (isolator) | - | DC 4–20 mA | - | DC 4–20 mA | - | - | DIN rail/wall surface | - | |
468.87 € | 1 | 23 Days | [Current (AC/DC)] Current (DC) | 25 | ±0.1 | 4 to 20mA | 1 | 2 | AC 100–240 | CE | 84 | 29.5 | 106.5 | Dual-output isolation converter (isolator) | - | DC 4–20 mA | - | DC0 to 10V | - | - | DIN rail/wall surface | - | ||
468.87 € | 1 | 23 Days | [Current (AC/DC)] Current (DC) | 25 | ±0.1 | 4 to 20mA | 1 | 2 | AC 100–240 | CE | 84 | 29.5 | 106.5 | Dual-output isolation converter (isolator) | - | DC 4–20 mA | - | DC±10 V | - | - | DIN rail/wall surface | - | ||
468.87 € | 1 | Available | 23 Days | [Current (AC/DC)] Current (DC) | 25 | ±0.1 | 0 to 10 V | 1 | 2 | AC 100–240 | CE | 84 | 29.5 | 106.5 | Dual-output isolation converter (isolator) | - | DC 4–20 mA | - | DC0 to 10V | - | - | DIN rail/wall surface | - | |
468.87 € | 1 | Available | 23 Days | [Current (AC/DC)] Current (DC) | 25 | ±0.1 | 0 to 10 V | 1 | 2 | AC 100–240 | CE | 84 | 29.5 | 106.5 | Dual-output isolation converter (isolator) | - | DC 4–20 mA | - | DC±10 V | - | - | DIN rail/wall surface | - | |
468.87 € | 1 | Available | 23 Days | [Current (AC/DC)] Current (DC) | 25 | ±0.1 | ±10 V | 1 | 2 | AC 100–240 | CE | 84 | 29.5 | 106.5 | Dual-output isolation converter (isolator) | - | DC 4–20 mA | - | DC±10 V | - | - | DIN rail/wall surface | - | |
277.42 € | 1 | Available | 5 Days | Pulse | - | - | [Other] Open Collector Output | 1 | 2 | AC 100–240 | CE | 84 | 29.5 | 106.5 | Pulse isolator | - | - | - | Open Collector | - | - | DIN rail/wall surface | Available power supply for sensor | |
277.42 € | 1 | Available | 23 Days | Pulse | - | - | [Other] Open Collector Output | 1 | 2 | AC 100–240 | CE | 84 | 29.5 | 106.5 | Pulse isolator | - | - | - | 12 V voltage pulse output | - | - | DIN rail/wall surface | Available power supply for sensor | |
438.23 € | 1 | Available | 23 Days | Voltage (DC) | 50 | ±0.1 | [Other] 2-point setting relay H, H operation | 1 | 2 | AC 100–240 | CE | 84 | 29.5 | 118 | Alarm setter | - | DC0 to 10V | - | - | - | - | DIN rail/wall surface | The response time is the time until the alarm is output at the moment the 0–100% input fluctuation corresponds to 50% of the alarm setting value. | |
438.23 € | 1 | Available | 23 Days | Voltage (DC) | 50 | ±0.1 | [Other] 2-point setting relay H, L operation | 1 | 2 | AC 100–240 | CE | 84 | 29.5 | 118 | Alarm setter | - | DC0 to 10V | - | - | - | - | DIN rail/wall surface | The response time is the time until the alarm is output at the moment the 0–100% input fluctuation corresponds to 50% of the alarm setting value. | |
438.23 € | 1 | Available | 23 Days | Voltage (DC) | 50 | ±0.1 | [Other] 2-point setting relay L, L operation | 1 | 2 | AC 100–240 | CE | 84 | 29.5 | 118 | Alarm setter | - | DC0 to 10V | - | - | - | - | DIN rail/wall surface | The response time is the time until the alarm is output at the moment the 0–100% input fluctuation corresponds to 50% of the alarm setting value. | |
438.23 € | 1 | Available | 23 Days | [Current (AC/DC)] Current (DC) | 50 | ±0.1 | [Other] 2-point setting relay H, H operation | 1 | 2 | AC 100–240 | CE | 84 | 29.5 | 118 | Alarm setter | - | DC 4–20 mA | - | - | - | - | DIN rail/wall surface | The response time is the time until the alarm is output at the moment the 0–100% input fluctuation corresponds to 50% of the alarm setting value. | |
438.23 € | 1 | Available | 23 Days | [Current (AC/DC)] Current (DC) | 50 | ±0.1 | [Other] 2-point setting relay H, L operation | 1 | 2 | AC 100–240 | CE | 84 | 29.5 | 118 | Alarm setter | - | DC 4–20 mA | - | - | - | - | DIN rail/wall surface | The response time is the time until the alarm is output at the moment the 0–100% input fluctuation corresponds to 50% of the alarm setting value. | |
438.23 € | 1 | Available | 23 Days | [Current (AC/DC)] Current (DC) | 50 | ±0.1 | [Other] 2-point setting relay L, L operation | 1 | 2 | AC 100–240 | CE | 84 | 29.5 | 118 | Alarm setter | - | DC 4–20 mA | - | - | - | - | DIN rail/wall surface | The response time is the time until the alarm is output at the moment the 0–100% input fluctuation corresponds to 50% of the alarm setting value. | |
288.91 € | 1 | Available | 23 Days | Voltage (DC) | 25 | ±0.1 | 4 to 20mA | 1 | 1 | AC 100–240 | CE | 84 | 23 | 106.5 | Isolation converter (isolator) | - | DC1 to 5V | - | - | - | 3.8VA(AC) | DIN rail/wall surface | - | |
288.91 € | 1 | Available | 23 Days | Voltage (DC) | 25 | ±0.1 | [Other] 1 to 5 V | 1 | 1 | AC 100–240 | CE | 84 | 23 | 106.5 | Isolation converter (isolator) | - | DC1 to 5V | - | - | - | 3.8VA(AC) | DIN rail/wall surface | - | |
288.91 € | 1 | Available | 23 Days | Voltage (DC) | 25 | ±0.1 | 0 to 10 V | 1 | 1 | AC 100–240 | CE | 84 | 23 | 106.5 | Isolation converter (isolator) | - | DC1 to 5V | - | - | - | 3.8VA(AC) | DIN rail/wall surface | - | |
288.91 € | 1 | Available | 23 Days | Voltage (DC) | 25 | ±0.1 | 4 to 20mA | 1 | 1 | AC 100–240 | CE | 84 | 23 | 106.5 | Isolation converter (isolator) | - | DC0 to 10V | - | - | - | 3.8VA(AC) | DIN rail/wall surface | - | |
288.91 € | 1 | Available | 23 Days | Voltage (DC) | 25 | ±0.1 | [Other] 1 to 5 V | 1 | 1 | AC 100–240 | CE | 84 | 23 | 106.5 | Isolation converter (isolator) | - | DC0 to 10V | - | - | - | 3.8VA(AC) | DIN rail/wall surface | - | |
288.91 € | 1 | Available | 5 Days | Voltage (DC) | 25 | ±0.1 | 0 to 10 V | 1 | 1 | AC 100–240 | CE | 84 | 23 | 106.5 | Isolation converter (isolator) | - | DC0 to 10V | - | - | - | 3.8VA(AC) | DIN rail/wall surface | - | |
288.91 € | 1 | Available | 23 Days | [Current (AC/DC)] Current (DC) | 25 | ±0.1 | 4 to 20mA | 1 | 1 | AC 100–240 | CE | 84 | 23 | 106.5 | Isolation converter (isolator) | - | DC 4–20 mA | - | - | - | 3.8VA(AC) | DIN rail/wall surface | - | |
288.91 € | 1 | Available | 23 Days | [Current (AC/DC)] Current (DC) | 25 | ±0.1 | [Other] 1 to 5 V | 1 | 1 | AC 100–240 | CE | 84 | 23 | 106.5 | Isolation converter (isolator) | - | DC 4–20 mA | - | - | - | 3.8VA(AC) | DIN rail/wall surface | - | |
288.91 € | 1 | Available | 23 Days | [Current (AC/DC)] Current (DC) | 25 | ±0.1 | 0 to 10 V | 1 | 1 | AC 100–240 | CE | 84 | 23 | 106.5 | Isolation converter (isolator) | - | DC 4–20 mA | - | - | - | 3.8VA(AC) | DIN rail/wall surface | - |
Loading...
Insulation | Available |
---|
Configure
Basic Attributes
Input Type
Response Speed(ms)
Conversion accuracy(%FS)
Output type
Number Of Inputs(Point)
Number of Outputs(Point)
Standard
Dimension length(mm)
Dimension width(mm)
Dimension thickness(mm)
Classification
Temperature Range
First input signal range
Second input signal range
Second output signal
Input thermocouple
Power consumption (current)
Power Supply
Filter by standard shipping days
Optional Attributes