Ring Sensor

Ring Sensor
[Specifications]
・Operating Voltage(V): 10-35 DC
・Protection: IP 67

[Features]
・Wide operating temperature range
・High protection rating for the requirements of harsh industrial environments
・Reliable detection due to low sensor tolerances
・Reduced storage due to wide range of applications

Part Number

Once your search is narrowed to one product,
the corresponding part number is displayed here.

Part Number
I7R201
I7R202
I7R203
I7R204
I7R205
I7R206
I7R207
I7R208
I7R209
I7R210
I7R211
I7R212
I7R213
I7R214
I7R215
I7R216
I7R217
N7R20A
N7R21A
N7R22A
N7R23A
N7R28A
N7R29A
N7R30A
N7R31A
Part Number
Standard Unit Price
Minimum order quantityVolume Discount
Standard
Shipping Days
?
Protection Nominal Voltage DC
(V)
Electrical Design Max. Part Speed
(m/s)
Resolution of Steel Ball (Diameter)
(mm)
Materials Current Consumption
(mA)
Electrical Connection - Plug Operating Voltage
(V)
Electrical Connection Hysteresis
(mm)
Ambient Temperature
(°C)
Reverse Polarity Protection Switching Amplifiers Connection to Switching Amplifiers Output Function Max. Travel Speed
(m/s)
Operating Principle Measuring Ball (Diameter)
(mm)
Short-Circuit Protection Max. Relative Air Humidity
(%)
Max. Voltage Drop Switching Output DC
(V)
Inside Diameter
(mm)
Permanent Current Rating of Switching Output DC
(mA)
Overload Protection Dimensions
(mm)
Display

154.23 €

1 4 Days IP 67-PNP351.5Housing: PA; ring: POM< 11Connector: 1 x M1210-35 DC---25-70Yes--normally open / normally closed; (selectable)-static-Yes-210.1200Yes60 x 35 x 20Switching status: 1 x LED, yellow

154.23 €

1 4 Days IP 67-NPN351.5Housing: PA; ring: POM< 11Connector: 1 x M1210-35 DC---25-70Yes--normally open / normally closed; (selectable)-static-Yes-210.1200Yes60 x 35 x 20Switching status: 1 x LED, yellow

161.70 €

1 4 Days IP 67-PNP350.6Housing: PA; ring: POM< 20Connector: 1 x M1210-35 DC---25-70Yes--normally open / normally closed; (selectable)-dynamic-Yes-210.1200Yes60 x 35 x 20Switching status: 1 x LED, yellow

161.70 €

1 4 Days IP 67-NPN350.6Housing: PA; ring: POM< 20Connector: 1 x M1210-35 DC---25-70Yes--normally open / normally closed; (selectable)-dynamic-Yes-210.1200Yes60 x 35 x 20Switching status: 1 x LED, yellow

154.23 €

1 4 Days IP 67-PNP352Housing: PA; ring: POM< 11Connector: 1 x M1210-35 DC---25-70Yes--normally open / normally closed; (selectable)-static-Yes-215.1200Yes60 x 35 x 20Switching status: 1 x LED, yellow

154.23 €

1 4 Days IP 67-NPN352Housing: PA; ring: POM< 11Connector: 1 x M1210-35 DC---25-70Yes--normally open / normally closed; (selectable)-static-Yes-215.1200Yes60 x 35 x 20Switching status: 1 x LED, yellow

161.70 €

1 4 Days IP 67-PNP350.8Housing: PA; ring: POM< 20Connector: 1 x M1210-35 DC---25-70Yes--normally open / normally closed; (selectable)-dynamic-Yes-215.1200Yes60 x 35 x 20Switching status: 1 x LED, yellow

161.70 €

1 4 Days IP 67-NPN350.8Housing: PA; ring: POM< 20Connector: 1 x M1210-35 DC---25-70Yes--normally open / normally closed; (selectable)-dynamic-Yes-215.1200Yes60 x 35 x 20Switching status: 1 x LED, yellow

154.23 €

1 4 Days IP 67-PNP352.5Housing: PA; ring: POM< 11Connector: 1 x M1210-35 DC---25-70Yes--normally open / normally closed; (selectable)-static-Yes-220.1200Yes60 x 35 x 20Switching status: 1 x LED, yellow

154.23 €

1 4 Days IP 67-NPN352.5Housing: PA; ring: POM< 11Connector: 1 x M1210-35 DC---25-70Yes--normally open / normally closed; (selectable)-static-Yes-220.1200Yes60 x 35 x 20Switching status: 1 x LED, yellow

161.70 €

1 4 Days IP 67-PNP351Housing: PA; ring: POM< 20Connector: 1 x M1210-35 DC---25-70Yes--normally open / normally closed; (selectable)-dynamic-Yes-220.1200Yes60 x 35 x 20Switching status: 1 x LED, yellow

161.70 €

1 4 Days IP 67-NPN351Housing: PA; ring: POM< 20Connector: 1 x M1210-35 DC---25-70Yes--normally open / normally closed; (selectable)-dynamic-Yes-220.1200Yes60 x 35 x 20Switching status: 1 x LED, yellow

154.23 €

1 4 Days IP 67-PNP353Housing: PA; ring: POM< 11Connector: 1 x M1210-35 DC---25-70Yes--normally open / normally closed; (selectable)-static-Yes50; (Ambient temperature 70 °C)225.1200Yes60 x 35 x 20Switching status: 1 x LED, yellow

154.23 €

1 4 Days IP 67-NPN353Housing: PA; ring: POM< 11Connector: 1 x M1210-35 DC---25-70Yes--normally open / normally closed; (selectable)-static-Yes50; (Ambient temperature 70 °C)225.1200Yes60 x 35 x 20Switching status: 1 x LED, yellow

161.70 €

1 4 Days IP 67-PNP351.2Housing: PA; ring: POM< 20Connector: 1 x M1210-35 DC---25-70Yes--normally open / normally closed; (selectable)-dynamic-Yes50; (Ambient temperature 70 °C)225.1200Yes60 x 35 x 20Switching status: 1 x LED, yellow

161.70 €

1 4 Days IP 67-NPN351.2Housing: PA; ring: POM< 20Connector: 1 x M1210-35 DC---25-70Yes--normally open / normally closed; (selectable)-dynamic-Yes50; (Ambient temperature 70 °C)225.1200Yes60 x 35 x 20Switching status: 1 x LED, yellow

239.42 €

1 4 Days IP 67-PNP356Housing: PA; ring: POM< 11Connector: 1 x M1210-35 DC---25-70Yes--normally open / normally closed; (selectable)-static-Yes-251200Yes110 x 80 x 20Switching status: 1 x LED, yellow

92.63 €

1 3 Days -8.2; (1kΩ)NAMUR--PA 12-GF30< 1.2; (disabled; conductive: > 2.1)--Cable: 0.15 m; 2 x 0.14 mm², PTFE1-40-100-connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mWYesnormally closed25-4---10--32 x 25 x 20-

155.66 €

1 3 Days -8.2; (1kΩ)NAMUR--PA 12-GF30value for direction of movement A : < 1.2; value for direction of movement B : > 2.1--Cable: 0.15 m; 2 x 0.14 mm², PTFE2-40-100-connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mWYesnormally closed10bistable4---10--32 x 25 x 20-

92.63 €

1 3 Days -8.2; (1kΩ)NAMUR--PA 12-GF30< 1.2; (disabled; conductive: > 2.1)--Cable: 0.15 m; 2 x 0.14 mm², PTFE1-40-100-connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mWYesnormally closed25-6---15--32 x 25 x 20-

155.66 €

1 3 Days -8.2; (1kΩ)NAMUR--PA 12-GF30value for direction of movement A : < 1.2; value for direction of movement B : > 2.1--Cable: 0.15 m; 2 x 0.14 mm², PTFE2-40-100-connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mWYesnormally closed10bistable6---15--32 x 25 x 20-

98.80 €

1 62 Days -8.2; (1kΩ)NAMUR--PA 12-GF30< 1.2; (disabled; conductive: > 2.1)--Cable: 2 m; 2 x 0.14 mm²1-40-100-connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mWYesnormally closed25-4---10--32 x 25 x 20-

162.17 €

1 62 Days -8.2; (1kΩ)NAMUR--PA 12-GF30value for direction of movement A : < 1.2; value for direction of movement B : > 2.1--Cable: 2 m; 2 x 0.14 mm²2-40-100-connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mWYesnormally closed10bistable4---10--32 x 25 x 20-

98.80 €

1 62 Days -8.2; (1kΩ)NAMUR--PA 12-GF30< 1.2; (disabled; conductive: > 2.1)--Cable: 2 m; 2 x 0.14 mm²1-40-100-connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mWYesnormally closed25-6---15--32 x 25 x 20-

162.17 €

1 62 Days -8.2; (1kΩ)NAMUR--PA 12-GF30value for direction of movement A : < 1.2; value for direction of movement B : > 2.1--Cable: 2 m; 2 x 0.14 mm²2-40-100-connection to certified intrinsically safe circuits with the max. values: U = 15 V / I = 50 mA / P = 120 mWYesnormally closed10bistable6---15--32 x 25 x 20-

Loading...