Safety Door Switch

Safety Door Switch
Blocks the control circuit by directly opening the contact by using the operation key only used to open the protective door of machine tools

[Features]
· Approved by TÜV
· Approved by UL, CSA.
· Direct opening of contact of switch at the time of opening protective cover by using the direct opening operation mechanism (only at NC contact side).
· Approval of EN standard of direct opening operation is shown by mark on the switch.
· Prevents error operation and fake operation by using exclusive operation key.
· A wide temperature range of -40 to+80°C.
· The protective structure of switch box is approved by IP67 (EN60947-5-1).

Part Number

Once your search is narrowed to one product,
the corresponding part number is displayed here.

Part Number
D4BS-1AFS
D4BS-2AFS
D4BS-15FS
D4BS-25FS
D4BS-K1
D4BS-K2
Part Number
Standard Unit Price
Minimum order quantityVolume Discount
Standard
Shipping Days
?
Detector Shape Force necessary for press side, O.F.
(N)
Movement up to switching, P.T.
(mm)
Maximum stroke T.T
(mm)
Contact type Main Body External Shape Width W
(mm)
Main Body External Shape Height H
(mm)
Main Body External Shape Depth D
(mm)
Conduit size Terminal Specification Details Type Mounting Method Direction of Operation Contact format

110.60 €

1 7 Days [Other] Key19.6110±523Mutual insulation double-throw40 -0/+141111.5Pg13.5Ground terminal (with screws)Main BodyFrontSlow action2NC

115.80 €

1 7 Days [Other] Key19.6110±523Mutual insulation double-throw40 -0/+141111.5G1/2Ground terminal (with screws)Main BodyFrontSlow action2NC

107.00 €

1 6 Days [Other] Key19.6110±523Mutual insulation double-throw40 -0/+141111.5Pg13.5Ground terminal (with screws)Main BodyFrontSlow action1NC/1NO

108.90 €

1 7 Days [Other] Key19.6110±523Mutual insulation double-throw40 -0/+141111.5G1/2Ground terminal (with screws)Main BodyFrontSlow action1NC/1NO

9.60 €

10 7 Days -----262078.7--Operation key main bodyHorizontal Mounting--

10.57 €

10 7 Days -----262053.7--Operation key main bodyVertical Mounting--

Loading...

  1. 1

Basic information

Main Body Size Standard Environment Standard / Cold Resistance Operating Temperature Range(°C) -40::80
Acquisition of Standard Approval TUV / UL / GB(CCC) / CQC / CSA / EN Protective Structure IP67 Mechanical Life(x10K times) 100
Operation Frequency of Machine(times/min. or Less) 30 Rated Operating Voltage(V) 100/125 V AC / More than AC300V Rated Current(A) 10
Cable Specifications - Detector element details - Display Light -
Movement After the Operation OT(mm) - Operating Position OP(mm) - Torque necessary for operation, OF(N▪m) -
Rubber material (scraper) - Box shape - Roller Type -