Manifold Hydraulic / Outlets 3 Sides / No Inlets

Manifold Hydraulic / Outlets 3 Sides / No Inlets
Hydraulic manifold blocks. G (PF) thread machining can also be specified.
  • Order quantities extended (D-JIT)

Part Number

Once your search is narrowed to one product,
the corresponding part number is displayed here.

G-BMAFLKPYN6-Q[2,​3,​4,​6]-R[2,​3,​4,​6]-S[2,​3,​4,​6]-P[40-60/1]

TypeMaterialSurface TreatmentMax. Operating Pressure
Pitch (P) StandardPitch (P) Configurable
25 × 32 Sq.40 Sq.50 Sq.60 Sq.70 Sq.40 Sq.50 Sq.60 Sq.
BMASBMAFABMAFLBMAFLKBMALBMAFPABMAFLPBMAFLKPSteel for General StructureTrivalent Chromate20.6 MPa ≈ 210 kgf/cm2 or less
BMAFMABMAFLMBMALMBMAFLMPElectroless Nickel Plating
BMASRBMAFRABMAFLRSUS304
BMAFSASUS316
BMAFCABrass1 MPa ≈ 10 kgf/cm2 or less

Specification Table

Part NumberQRSP  
     
Type Mounting Hole Change Number of Circuits
BMAF
BMAFLP
G−BMAFLP

NA
NA
 4
3
3


Q3
Q3
Q3


R2
R4
R4


S3
S4
S4



P45
P45
 

(G Thread)
Part NumberRc (PT), NPT SelectionPitch PNumber of Pitches
N
Total Number of
Q, R and S Threads
ABEFXYMounting Hole
TypeMounting Hole ChangeNumber of CircuitsQ, R, SStandardConfigurable 1mm IncrementM
(25x32 Sq.)NA (Through)


T (Tapped)


ZT (Counterbore Tapped)


YZ (Side Counterbore)


YN (Side Through)
11 (1/8)--03253220167.57M5
Pitch Standard
BMAS
BMASR
 22516
329
4312
5415
6518
7621
8724
(40 Sq.)1 --03404025207.57M6
Pitch Standard
BMAFA
BMAFMA
BMAFRA
BMAFSA
BMAFCA
Pitch Configurable
BMAFPA


 
21 (1/8)4025~5016
32 (1/4)29
43 (3/8)312
51N (NPT1/8)415
62N (NPT1/4)30~50518
73N (NPT3/8)621
(Standard Change: E dimension)8 724
(50 Sq.)1 --03505030257.58M8
Pitch Standard
BMAFL
BMAFLM
BMAFLR
Pitch Configurable
BMAFLP
BMAFLMP
22 (1/4)6035~6016
33 (3/8)29
44 (1/2)312
56 (3/4)415
6 40~60518
(60 Sq.)1 --03606030307.58M8
Pitch Standard
BMAFLK
Pitch Configurable
BMAFLKP
22 (1/4)6035~6016
33 (3/8)29
44 (1/2)312
56 (3/4)415
6 40~60518
(70 Sq.)1 --03707040351010M8
Pitch Standard
BMAL
BMALM
 26 (3/4)6016
38 (1)29
4 312
By inserting "G-" before part number, the thread type can be changed to the G (PF) Thread as part of ordering.(Ex.: G-BMAF)For ordering, see the Ordering Example.
For Q, R and S, specify 1, 2, 3, 4, 6, 8, 1N, 2N or 3N indicated before ( ).
Single Circuit is not available for Pitch Configurable Type.
SUS316 or Brass is for up to 6 connections.
Specify the pitch taking into consideration the necessary dimensions for fitting the couplings.
Each 6 and 8 Circuit Type has an additional mounting hole at the midpoint of the overall length. 7 Circuit Type has an additional mounting hole at each midpoint of the 2 - 3 port pitch, and 5 - 6 port pitch from the left to the right.
For Block Square 50 Type, when 3/4 is selected for both tapered threads at right angles, the tapered male threads may interfere with each other. Select Block Square 60 Type instead.
Select NA, T or ZT for the mounting hole shape of 7 and 8 Circuit Types .

Part Number:  

    3D preview is not available, because the part number has not yet been determined.

  • In order to open the 3D preview, the part number must be fixed.
Loading...
Part Number
G-BMAFLKPYN6-Q[2,​3,​4,​6]-R[2,​3,​4,​6]-S[2,​3,​4,​6]-P[40-60/1]
Part NumberMinimum order quantityVolume Discount
Standard
Shipping Days
?
RoHSShape Material Surface Treatment Block Size
(mm)
Number of Circuits
(Circuits)
Thread Size / Type Mounting Hole Change Pitch P
(mm)
Pitch Standard / Configurable Application Select a value for PT/PF Thread Dia. on Q (in Drawing). [Q] 1(1/8) 2(1/4) 3(3/8) 4(1/2) 6(3/4) 8(1) Select a value for PT/PF Thread Dia. on R (in Drawing). [R] 1(1/8) 2(1/4) 3(3/8) 4(1/2) 6(3/4) 8(1) Select a value for PT/PF Thread Dia. on S (in Drawing). [S] 1(1/8) 2(1/4) 3(3/8) 4(1/2) 6(3/4) 8(1)
1 9 Days 10Intlets - None Outlets - Top & SideSteel for General StructureTrivalent Chromate60 x 606G (PF) ThreadYN (Side Through)40 ~ 60Configurable TypeFor hydraulic / Water Pressure2 ~ 62 ~ 62 ~ 6

Loading...

  1. 1

Complementary Products

Tech Support

Technical Support
Tel:+49 69 668173-0 / FAX:+49 69 668173-360